POWER RECTIFIERS

02 / 06

Industrial Rectifiers

Process-engineered high-current DC power systems for electrochemistry, metallurgy, coating, heating and water treatment.

Industrial Rectifiers
POWER RECTIFIERSConfigured for duty · Engineered to deliver

SYSTEM OVERVIEW

Start with the duty. Build the right system configuration.

Industrial rectification is configured around the process load rather than a catalogue rating alone. Kerrix aligns voltage and current range, regulation accuracy, duty profile, cooling, transformer arrangement and plant control interfaces with the operating process.

EQUIPMENT RANGE

Equipment & typical specifications

Values shown are typical for the current portfolio. Final models, ratings and interfaces are subject to project requirements and technical confirmation.

01High-Power Industrial Rectifier

High-Power Industrial Rectifier

Process-engineered rectifier platform for electrolysis, smelting, coating, heating and industrial water treatment.

  • 100–2,000 V / up to 100,000 A DC
  • Voltage regulation ±0.3%; current ±0.5%
  • >96% efficiency across 40–100% load
Inquire about this product

APPLICATIONS

Built around real operating contexts

Application boundaries, equipment configuration and system interfaces are confirmed during project engineering.

01

Electrolysis and metallurgy

High-current DC supply for non-ferrous metal electrolysis and rare-earth smelting processes.

02

Chlor-alkali and water treatment

Regulated rectification for chlor-alkali and electrocoagulation duties.

03

Coating processes

Stable DC power for electrophoretic and vacuum-coating applications.

04

Industrial heating

Configurable DC output for graphite heating and other process loads.

PROJECT INPUTS

What defines the right selection?

Share these inputs early so Kerrix can define the technical route, equipment configuration and interface boundaries.

  1. 01

    Required DC voltage and current range at the process load

  2. 02

    Regulation accuracy, ripple limits and operating duty profile

  3. 03

    Transformer, rectifier topology and harmonic-management boundary

  4. 04

    Cooling arrangement and local ambient conditions

  5. 05

    Plant control, protection, communication and maintenance interfaces

ENGINEERED TO DELIVER

From requirement definition to continued operation

Kerrix supports solution design, system integration, commissioning, remote diagnostics and spare-parts support so equipment selection remains aligned with project delivery.

01Requirements & duty
02Equipment & interfaces
03Integration & commissioning
04Diagnostics & spares

PROJECT FAQ

Frequently asked questions

01What output range is available?

The current industrial rectifier platform covers typical DC outputs from 100 to 2,000 V and currents up to 100,000 A, subject to project engineering.

02Is the rectifier selected by current rating alone?

No. Process duty, regulation performance, ripple, cooling, transformer arrangement and control interfaces are evaluated together.

03Can the system interface with plant control?

Control and communication interfaces are defined with the project so the rectifier can be coordinated with plant operating and protection requirements.

PROJECT INQUIRY

Start with the duty. Define the right system.

Send the application, electrical parameters, site conditions and delivery boundary to begin the technical discussion.

sales@kerrixels.com